Remote control mower radio interference is the first thing blamed when a machine stops mid-run and the last thing checked. The handset is a 2.4 GHz proportional unit with a working range of 200–500 m line of sight, and when the link drops the deck stops. That is deliberate behaviour, not a fault. The useful question is why the link dropped, and on most sites the answer is a feature of the ground rather than a failure inside the machine.
What follows is a diagnostic sequence rather than a list of fixes: what the link physically is, the site conditions that break it, and the checks that separate interference from a flat handset battery or a receiver that never paired. Most of it happens on foot, in ten minutes.
What the link is, and what line of sight leaves out

The published range is 200–500 m line of sight. That is a band, not a promise: plan around the lower figure and expect the upper one only on open ground with nothing in between.
At 2.4 GHz the wavelength is roughly 12.5 cm, short enough that the signal behaves more like light than sound. It does not bend around a bank and does not pass through a steel container. It loses energy to anything holding water, which includes a hedge in leaf, wet grass at chest height and the person holding the handset.
Line of sight also understates the requirement. A radio link needs a corridor, not a thread: the zone around the straight line has to be substantially clear, so a hedge that clears the visual line by half a metre still costs signal. Where a rise sits between operator and machine, the visual line can be open while the corridor is half in the soil.
Metal is the other half of the story. Steel reflects 2.4 GHz rather than absorbing it, so a signal meeting a pile or a panel frame arrives twice, once direct and once a moment later, and the second copy can cancel the first. That is why a machine can hold its full working distance in the open and lose control at a fraction of it beside a steel frame.
The four site conditions that break the link
In rough order of how often they turn out to be the cause.
Mass steel in the path. Piles, reinforcement cages, scaffolding, containers. One large steel object between handset and machine is usually enough, and it does not have to be close to either end.
Long parallel metal structures. Solar panel rows, railway line, silo walls, shed frames. These block the direct path and reflect energy down the corridor between them, so the receiver sees a mix of arrivals at different delays. Panel rows are the classic case, because the machine is designed to work inside them.
Wet vegetation and standing water. A dry hedge costs some signal; the same hedge after rain costs more. This is why a site that worked in June fails in November, and why the fault appears to move around.
Other 2.4 GHz traffic. Site wifi, wireless cameras, telemetry gateways and handheld terminals share the band. Interference from these tends to follow working hours rather than position, which is a useful distinction when placing the blame.
Why solar sites are the usual suspect
An array is a lattice of steel posts carrying glass and aluminium, set in parallel rows across a field. Working between two rows puts the machine inside a metal corridor with a reflective wall each side, and puts the operator at one end holding a handset at waist height. The direct path runs down the row, close to both walls.
The result is predictable. Signal is fine at the row end, fades as the machine moves down the row, then recovers when it turns into the open. Operators read that as the machine losing range; what is happening is the corridor closing around the path. The same machine will run to its full working distance across open grass.
Construction adds to it. Pile driving rigs, welding sets, inverters, string cabling and temporary site networks are all present while vegetation is being held down around new arrays, and the permanent comms are often not in yet. The working method that avoids most of this is set out on the solar farm mowing page.
Reading the symptom before you walk the site
The way the machine fails carries most of the diagnosis. Four patterns cover nearly every case.
| What you see | What it points to | First check |
|---|---|---|
| Deck stops, handset still on | Link lost | Walk back; note the distance at which it re-arms |
| Controls lag, then recover | Marginal link, no break yet | Note where you stood and which way you faced |
| Stops at the same point every pass | Fixed obstruction | Mark the spot; look for steel or a rise in the path |
| Stops at random, anywhere on site | Other traffic, or a handset fault | Test with the machine stationary and close |
The distance at which the deck re-arms is the most useful number to write down. If it differs from one row end to the next, the machine is fine and the site is not uniform.
A ten-minute check that isolates the cause
Work through these in order and stop when the behaviour changes.
1. Reproduce it at walking pace. Drive slowly into the failure zone with the deck raised. If it still stops, the problem is the link and not load on the deck.
2. Walk the path, not the machine. Stand where the operator stood and sight the straight line. Steel, a rise, a wet hedge, a parked trailer. This step finds the cause more often than any instrument.
3. Raise the handset. Chest or shoulder height, antenna vertical, clear of your body. A handset held against a coat at waist height has a person and a layer of wet fabric in the near field.
4. Step off the row axis. Move two or three metres to the side so the path no longer runs down the corridor. If control returns at once, the rows are the cause and nothing needs repairing.
5. Repeat the same distance in the open. If the machine holds there, it is serviceable and the layout is the constraint.
If all five pass and it still stops in the same place, the next suspect is the handset or the pairing. That is a different fault tree, covered in the five things that stop a mower on site.
What is not interference
Two failures get mislabelled constantly. A handset that has lost pairing may start the machine and then refuse a direction, which looks like a signal problem but does not vary with distance. A handset battery close to flat behaves the same way. Both symptoms move when you move, which is exactly what interference does.
Distance separates them. Interference is repeatable at a place; a pairing or battery fault is repeatable at a time, wherever the machine happens to be. If the fault follows the handset rather than the ground, the site is innocent.
A stop is not a failure. Link loss stops the deck by design, and a machine that stops when the operator walks behind a container is behaving correctly. The fix is a working method, not a repair.
What the regulations do and do not guarantee
A handset sold in the EU is radio equipment under the Radio Equipment Directive 2014/53/EU, which requires efficient use of spectrum and a defined level of immunity. The machine as a whole falls under the EMC Directive 2014/30/EU. Every MAGNUS unit ships with CE documentation including the declaration of conformity, the operating manual and the noise and vibration figures.
What those directives require is immunity to a defined level of disturbance, not immunity to everything. A compliant machine can still be stopped by a site condition outside that envelope, and that is not a defect. Compliance sets a floor; the site decides what happens above it.
There is a duty-of-care layer as well. Under PUWER, work equipment has to be suitable for the work and maintained in an efficient state. Working a machine where control is unreliable is a siting decision to be managed, whether or not the equipment is compliant.
When the site wins
Sometimes the layout cannot be changed and the answer is a shorter working distance. Two adjustments cover most of it.
Work each row from the end rather than following the machine down it, so the path stays out of the corridor for as long as possible. Then set the work area from the lower end of the 200–500 m band on any site with steel in it, rather than discovering the limit mid-row. Where rows are tight enough that the machine stays inside them for a whole pass, a narrower deck keeps it closer to the row end: the 500 mm MA-50P exists for that work, and the same constraint applies to narrow verges.
The wider safety case for remote working on sites like these, including what to do when control is lost, is in remote control mower safety. Interference is one reason the operator position matters more than the machine.
If a site still defeats the link after all of that, send the layout, the distance at which the deck re-arms and what stands between the two points. That is enough to say whether a different working method will fix it. The contact page reaches us; there is no need to buy anything to ask.
Related guides
Read next
Tracked mower track tension: how to read the wear
How to check tracked mower track tension by hand, what a slack track sounds like, and the wear pattern that…
When to sharpen remote control mower blades
How to tell a dull blade from a damaged one, the three signs a remote control mower blade is past…
Tracked or wheeled: which mower actually holds a slope
Tracks and wheels fail in different ways. What a wheel does on a bank, what a track does instead, and…
Send the slope. We will confirm the model.
Tell us the gradient, the area and the nearest port. We reply with a model and a landed cost within one business day.